Characteristics IPB-1K. Noncontact Density meter IPB-1K Ecophyspribor

The Density meter IPB-1K is available in four models that differ in the detector unit used and in the fractional error tolerance.

Version 10
Designation - IPB-1K-10 KZRS.843000.001-10
with BD-6-5D KZRS.329.000.006-25 or BD-6-1D KZRS.329.000.006-21 Detector unit)

Version 11
Designation - IPB-1K-11 KZRS.843000.001- 11
(with BD-6-5 KZRS.329.000.006-05 or BD-6-1 KZRS.329.000.006-01 Detector unit)

Version 12
Designation - IPB-1K-12 KZRS.843000.001-12
(with BD-7-5D KZRS.329.000.007-25 or BD-7-1D KZRS.329.000.00-21 Detector unit)

Version 13
Designation - IPB-1K-13 KZRS.843000.001- 13
(with BD-7-5 KZRS.329.000.007-05 or BD-7-1 KZRS.329.000.007-01 Detector unit)

In Versions 12 and 13, the Detector units feature an explosion-proof protection level, with the protection type of explosion-proof enclosure and protection label of РВЕхdI/1ExdIICT6.
The units feature an ingress protection of IP-65 as per GOST14254-96.

Performance specification (fragments)

1. Fluid or pulp density measurement range in 0.05m to 0.7m diameter pipelines and various process plants, kg/m3.............................................600 to 2,200

2. Fundamental absolute error tolerance (these data are valid for the specified values of pipeline diameters and density measurement ranges (were confirmed by Pattern Approval Certificate of Measuring Instruments RU.C/31.010.A No. 56231), kg/m3:

for 0.1m to 0.2m diameter pipelines at rated averaging time and rated activity of the radiation source:
Versions 10 and 12......................................................6.0
Versions 11 and 13......................................................10.0

for over 0.2m diameter pipelines and over 1,700kg/m3 density measurement range at rated averaging time and rated activity of the radiation source:
Versions 10 and 12......................................................12.0
Versions 11 and 13......................................................20.0

for over 0.2m diameter pipelines and under 1,700kg/m3 density measurement range at rated averaging time and rated activity of the radiation source:
Versions 10 and 12......................................................6.0
Versions 11 and 13......................................................10.0

3. Range of ambient temperatures at which Densitometer is serviceable

for Detector unit, С ......................................................-40 to +70
for Information handling unit, С ....................................-20 to +60
for low-temperature Information handling uniit, С ..........-40 to +50